| Model | CEZONE-012 | CEZONE-016 | CEZONE-024 | CEZONE-050 |
|---|---|---|---|---|
| Ozone generation rate (kg/h) |
1.2 | 1.6 | 2.4 | 5.0 |
| Ozone gas conc (g/m3) |
87.5g/m3 (nor) (6wt%) | |||
| Ozone gas flow rate) (m3/h) |
14.0 | 18.5 | 28.0 | 57.5 |
| Oxygen feedgas pressure (MPaG) |
0.30 | |||
| Ozone gas pressure (MPaG) |
0.12 | |||
| Ozone generation method | Silent discharge | |||
| Cooling method | Cooling water | |||
| Cooling water temp. | 12°C / 17°C | |||
| Ozone generation control method | Feed back control according to ozone gas conc. | |||
| Oxygen supply unit | Pressure Swing Absorption unit | |||
| Electric power | Three phase AC440V ± 10%,50/60Hz | |
|---|---|---|
| Oxygen gas | Gas composition | Oxygen:min.90wt%, max.93wt% Nitrogen:min.2.0wt% |
| Hydrocarbon: ≤ 15ppb | ||
| Dew point: ≤ -65°C at atmospheric pressure | ||
| Pressure: 0.3MPaG ± 5kPaG | ||
| Temp.: ≤ 40°C | ||
| Max. dust diameter:≤ 0.1µm | ||
| Cooling water | Temp.: Inlet 12°C ± 2°C | Outlet 17°C ± 2°C |
| Pressure: Inlet 0.15MPaG | Outlet 0.1MPaG | |
| Water lever: Ion exchanged water or pure water | ||
| Conductivity: ≤ 1.0µs/cm | ||