Electrolysis Ozone Water Generator
Feature

- Operates on an ozone water generation principle using a super pure water electrolysis method that is cleaner than the discharge method
- Supports a flow of more than 100mg/L ozone water and more than 80 L/min ozone water
- The ozone water density and amount of flow can be adjusted according to customer's needs.
- This is recommended for use as a high density/large flow batch type washer, high density/small flow sheet-fed type washer and low density/large flow continuous shower type.
- Compact design to save space
- High regurgitation pressure actualized with the high pressure ozone generator and booster pump
- High-speed startup (3 minutes) from start up
Usage
- Silicon wafer production field:
Epi pre-washing, ion injection pre-washing, washing after flatting, pure water sterilization
- Semiconductor production field:
Wash incoming wafer, wash before film generation, resisto crud removal, resisto removal, pure water line sterilization, washing after CMP
- LCD production field:
Wash incoming glass substrate, wash before film generation, pure water line sterilization
Electrolysis ozone water generation process

Standard model data
| Model Name |
Ozone water density
(mg/L) |
Amount of ozone water
(L/min.) |
Dimension (WxDxH mm) |
Weight (kg) |
Power capacity (kVA) |
CO2 gas feed |
| POW-2010-S |
20 |
10 |
900x1,000x1,900 |
650 |
11.9(3φAC200V) |
add/no |
| POW-6005-S-C |
60 |
5 |
900x1,000x1,900 |
700 |
12(3φAC200V) |
add |
| POW-10005-SP-C |
100 |
5 |
1,300x1,300x1,900 |
1,200 |
17.1(3φAC200V) |
add |
Utility
- Power (confirm voltage and frequency)
- Pure water (super pure water at more than 17MΩ/cm) Water temperature is lower than 25 degree. Content hydrogen peroxide density is less than 50ppb)
- Cooling water (23 degree ±3 degree)
- Control air (0.5-0.7MPa)
- Heat exhaust duct
- Drain line (gravity flow or pump discharge.)
Optional
- Ozone water booster unit
- Agent injection unit
- CO2 gas feed unit
- Water saving system
Type symbol

- Electrolysis ozone water generator (POW)
- Ozone density
Example: 10mg/L to 10, 20mg/L to 20, 60mg/L to 60
- Ozone water flow amount
Example: 10L/min.to 10, 20L/min.to 20, 5L/min. to 05
- Grade of semiconductor production unit (S)
- No symbol→Standard, P to Booster pump is embedded
return top page